Produse pentru acetonă lustruitor (3)

Protech Fix AC-Therm: Fixativ acrilic de întărire anti-condensare, în dispersie apoasă

Protech Fix AC-Therm: Fixativ acrilic de întărire anti-condensare, în dispersie apoasă

Protech Fix AC-Therm Water-based anti-condensing wall covering, with excellent fixing and anchoring properties, with good coverage based on high penetration acrylic resins, 3M Glass Bubble, pigments, fillers and covering fillers. Suitable as an anti-condensation fixative primer, prior to painting or coating the plaster with anti-condensation paints or plasters (-THERM). Ideal for interventions on walls with mucilage deposits, bacterial phenomena and moulds. Due to its low thermal conductivity, it is particularly suitable for solving mould problems. It can be applied on any plaster (rustic, civil, plaster, dry mortar, plasterboard, concrete, prefabricated, exposed concrete, etc.). Made with special resins and additives it reduces the absorption of the support while allowing the necessary transpiration, uniforms the absorption making the application of the finishing coats easier. It always works in depth, which is why it is the ideal preparation for applying water-based paints or coatings. Adhesion is excellent even on particularly difficult surfaces, thanks to the use of special resins and the presence in the formulation of an adhesion promoter interacting between the support and the product. Preliminary treatment of any surface (civil, plaster, rustic, dry mortars, plasterboard, concrete, prefabricated, exposed concrete etc.) designed to isolate the support surfaces and standardise the absorptions of the subsequent anti-condensate treatments (painting and protective coatings). Packaging: 14-liter bucket UM: €/l
Protech AC-P : Vopsea acrilică, lavabilă, pentru interior și exterior

Protech AC-P : Vopsea acrilică, lavabilă, pentru interior și exterior

Protech AC-P Paint based on acrylic resins in aqueous emulsion, for interiors and exteriors, protective lamellar structure which, in addition to having an aesthetic effect, allows maximum filling, transpiration and very high resistance to mechanical and chemical light. The high coverage and expandability make this product extremely easy to apply. The special acrylic resins that compose it allow to obtain a film characterized by a rapid insensitivity to water even during the drying phase, with a consequent reduction of the "snail effect" in the event of atmospheric events. Protective and decorative finish painting of walls, facades, concrete products, plasters, masonry, natural stone, porous substrates in general. For old plasters, pay particular attention to the old pre-existing paints, which must be removed by careful scraping and brushing in order to obtain a healthy and non-friable support; then proceed with the application of Protech Fix AC fixative. When applying on new plasters, it is good practice to insulate the base with acrylic insulator or even better with a white or neutral microemulsion fixative. Avoid windy or cold days when applying. Do not apply on fresh or particularly alkaline substrates, respect a minimum carbonation period of at least four weeks. On large surfaces it is recommended to apply product from the same batch and always proceed wet on wet to avoid signs of recovery. Never operate with temperatures below + 5 ° C. Rainy weather, excessive atmospheric humidity and temperatures below + 8 ° C can greatly compromise drying with the possibility of washing off by rainwater even after several days. . DILUTION (by volume with drinking water) BRUSH 1st COAT: 15% a crossed coat or two coats 12-24 hours apart 2nd COAT: 10%. ROLLER 1st COAT: 10% 2nd COAT: 10%. SPRAY (through specific equipment) 1st COAT: 15/25% 2nd COAT: 15/25%. To avoid filming defects, being resin-based products in aqueous emulsion, the application temperature must be between + 5 ° C and + 35 ° C with relative humidity not higher than 60/70%. Do not apply under the direct action of the sun and wind. Do not apply on fresh or particularly alkaline substrates, respect a minimum drying period of the substrate of at least four weeks. It is also advisable for colored, not to use on large surfaces dyed with different production batches as slight differences between batch and batch are technically possible. Please check the color before application as we will not respond to any disputes regarding the shade of the applied product. From 0.20 to 0.30 liters of Protech AC-P for each square meter of surface to be painted. Pail 14 l
Syntech Poliurea Top Coating: Strat de protecție pe bază de rășină poliuretanică alifatică

Syntech Poliurea Top Coating: Strat de protecție pe bază de rășină poliuretanică alifatică

Syntech Poliurea Top Coating A protective, pigmented, two-component formulation based on aliphatic polyurethane resins, ideal as a protective and aesthetic coating on waterproofing with SYNTECH POLIUREA SPRAY. Characterised by high levels of elasticity and elevated protection, even in aggressive atmospheres. Available on request in shades from the RAL colour range. Surface coating pigmented for colouring polyurethane claddings, and their protection from UV rays (which in the absence of the top coating would alter the colour over time). After suitable priming with SYNTECH POLYUREA PRIMER, it can also be applied as a simple coloured aliphatic protective coating. Polyurea support Vacuum and blow the surfaces to eliminate any dust that may have accumulated in the 24-48 hours following the installation of SYNTECH POLIUREA SPRAY Support in concrete, mortar, brick, tiles The support on which the polyurea system must be laid must be suitable for withstanding the stresses resulting from the intended use, such as static or dynamic loads, impacts, thermo-hygrometric dilations, vibrations, etc. As regards the characteristics of the substrate (maximum humidity, cohesion, strength class, flatness, etc.) and the preparation of the surface that will accommodate the resin system, we recommend the requirements set out in chapter 5 of the UNI 10966 standard ("RESIN SYSTEMS FOR SURFACES HORIZONTAL AND VERTICAL - INSTRUCTIONS FOR DESIGN AND APPLICATION "). In any case, carefully clean and degrease the surfaces, removing any kind of dirt, paint residues or incoherent parts. The humidity of the support must be <= 3%. Evaluate the most convenient type of mechanical preparation (shot peening, sandblasting, hydro-washing, etc.). The surfaces must also be free from discontinuity, and possibly leveled and regularized with products from the FLOOR line or the REPAR line. In case of presence (even suspected) of humidity deriving from capillary rising from the substrate, it is recommended to apply in advance the epoxy resin for "wet substrates" Syntech Pavidamp. Tiled floors, or floors covered with pre-existing resin, must be subjected to mechanical roughening carried out with shot blasting, milling, bush hammering, etc., until the total elimination of the waterproof crust and the opacification of the surfaces. Remove dust after abrasion. It is recommended to use Primer from the SYNTECH POLIUREA PRIMER range. On particularly absorbent substrates, to avoid the formation of craters / blowholes on the surface of the freshly sprayed product, it is recommended to use primers from the SYNTECH POLIUREA PRIMER range, always contacting the Azichem technical staff for clarification on the most suitable type to use. Apply several layers of primer until the porosity is saturated and providing a light dusting with clean and dry quartz sand (0.4-0.7 mm). Never dust off the primer. Provide suitable elastic sealing systems to cover joints, fittings, cracks or fissures subject to significant movements. Pour component B with component A into a single container, taking care to remove all the material from the packaging. Mix thoroughly with a mixer at low revs, until a lump-free mixture is obtained. Apply with a roller or brush on the surfaces of SYNTECH POLYUREA SPRAY, within 24-48 hours of spreading the latter. A thorough sanding of the supports is recommended for any repairs and/or finishes. From 0.15 to 0.25 kg of SYNTYECH POLIUREA TOP COATING for each square metre of surface to be covered. Can 6.7 kg [A] - Can 3.3 kg [B] - Kit: 1 Can 6.7 kg [A] + 1 Can 3.3 kg [B]